Charger 80A 24V Victron Energy Skylla-i 24/80 (1+1)
Charger 80A 24V Victron Energy Skylla-i 24/80 (1+1)

Charger 80A 24V Victron Energy Skylla-i 24/80 (1+1)

SKI024080000
€1,378.67
VAT included 22 %

€1,130.06 Vat excl.

A modern and powerful battery charger that withstands the rigors of an adverse environment: heat, humidity and salt air.

 

Are you a dealer or installer?

For bulk purchase of Victron Energy products called the n. 0882 228247, or write to [email protected]

Charger Skylla-i 24V 80A

Model: 24/80 (1+1)

A modern and powerful battery charger that withstands the rigors of an adverse environment: heat, humidity and salt air.

  • The right amount of charge for a lead-acid battery: variable absorption time
  • BatterySafe mode: preventing damage due to excessive gassing
  • Storage mode: less maintenance and aging when the battery is not in use
  • Smaller and lighter compared to similar models
  • NMEA2000 Canbus connection
  • PowerControl: set a maximum shore power
  • Remote Control
  • Li-ion (LiFePo4) ready

Technical Features

Product code: SKI024080000
Download Product Datasheet

Warranty

2 Years Guaranteed

Features

Skylla-i (1+1): two outputs to charge 2 battery banks
The Skylla-i (1+1) features 2 isolated outputs. The second output, limited to approximately 4 A and with a slightly lower output voltage, is intended to top up a starter battery.

Skylla-i (3): three full current outputs to charge 3 battery banks
The Skylla-i (3) features 3 isolated outputs. All outputs can supply the full rated output current.

Rugged
Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air.
Circuit boards are protected with an acrylic coating for maximum corrosion resistance.
Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions.

Flexible
Next to a CAN bus (NMEA2000) interface, a rotary switch, DIP switches and potentiometers are available to adapt the charge algorithm to a particular battery and its conditions of use.
Please refer to the manual for a complete overview of the possibilities.

Important features:

Synchronised parallel operation
Several chargers can be synchronised with the CAN bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables. Please see the manual for details.

The right amount of charge for a lead-acid battery: variable absorption time
When only shallow discharges occur the absorption time is kept short in order to prevent
overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged.

Preventing damage due to excessive gassing: the BatterySafe mode
If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-i will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached.

Less maintenance and aging when the battery is not in use: the Storage mode
The storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (26,4 V for 24 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure.

To increase battery life: temperature compensation
Every Skylla-i comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected.

Battery voltage sense
In order to compensate for voltage loss due to cable resistance, the Skylla-i is provided with a voltage sense facility so that the battery always receives the correct charge voltage.

Suitable for AC and DC supply (AC-DC and DC-DC operation)
The chargers also accept a DC supply.

Use as a power supply
As a result of the perfectly stabilized output voltage, the Skylla-i can be used as a power supply if batteries or large buffer capacitors are not available.

Li-Ion (LiFePO4) ready
Simple charger on-off control can be implemented by connecting a relay or open collector optocoupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the galvanically isolated CAN bus port.

Manual, Datasheet and Certifications

Data Sheet EN [LINK]

For all other documents to download, please visit the web site:
www.victronenergy.com

Assistance

  For service or plant configuration call 0882 22 82 47
  For technical assistance, write to [email protected]
8380000002276

You might also like

Product added to wishlist
Product added to compare.