We inform our kind customers that shipments are suspended for the holidays and will resume on January 7, 2025

Inverter/chargers MultiPlus II 3000VA 48V 2400W Victron Energy 48/3000/35-32
Inverter/chargers MultiPlus II 3000VA 48V 2400W Victron Energy 48/3000/35-32
Inverter/chargers MultiPlus II 3000VA 48V 2400W Victron Energy 48/3000/35-32
Inverter/chargers MultiPlus II 3000VA 48V 2400W Victron Energy 48/3000/35-32
Inverter/chargers MultiPlus II 3000VA 48V 2400W Victron Energy 48/3000/35-32
Inverter/chargers MultiPlus II 3000VA 48V 2400W Victron Energy 48/3000/35-32
Inverter/chargers MultiPlus II 3000VA 48V 2400W Victron Energy 48/3000/35-32
Inverter/chargers MultiPlus II 3000VA 48V 2400W Victron Energy 48/3000/35-32

Inverter/chargers MultiPlus-II GX 3000VA 48V 2400W Victron 48/3000/35-32 GX

PMP482306000
Last items in stock
€718.56
VAT included 10 %

€653.24 Vat excl.

Inverter/charger with GX inside

An Inverter/Charger with device networking built-in, the MultiPlus-II GX communicates with a solar charger, batteries, and other devices to control a grid-connected, off-grid, or remote power installation.

 

Inverter/Charger 3000VA 48V 2400W Victron Energy

MultiPlus II 48/3000/35-32 GX

Inverter/charger with GX inside

An Inverter/Charger with device networking built-in, the MultiPlus-II GX communicates with a solar charger, batteries, and other devices to control a grid-connected, off-grid, or remote power installation. Capable of parallel operation for increased power output, or battery charge-rates, the MultiPlus-II GX can also be configured for three-phase supply. A host of advanced features - such as uninterrupted power supply, setting load limits, and supplementing limited grid-power availability with battery power - can all be controlled straight from your phone or smart device. Remote monitoring is also possible.

A MultiPlus-II with LCD and GX functionality
The MultiPlus-II GX integrates a MultiPlus-II inverter/charger and a GX device with a 2 x 16 character display.

Display and Wi-Fi
The display reads battery, inverter and solar charge controller parameters.
The same parameters can be accessed with a smartphone or other Wi-Fi enabled device.

GX device
The integrated GX device includes:
• A VE.Can interface. This can be used to connect to Victron VE.Can devices (eg VE.Can MPPTs), or the port can be reconfigured via the Remote Console for use with a compatible CAN-bus Li-ion Battery.
• A USB port.
• A Ethernet port.
• A VE.Direct port.

Applications
The MultiPlus-II GX is intended for applications where additional interfacing with other products and/or remote monitoring is required, such as on-grid or off-grid energy storage systems and certain mobile applications.

Parallel and three phase operation
Only one GX unit is needed in case of Parallel and three phase operation.

PowerAssist



The MultiPlus-II will prevent overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload would occur.

The second level will boost the output of a generator or shore side supply with power taken from the battery.

ESS: Energy Storage Systems



The MultiPlus-II is the key component in a Victron ESS system, providing the flexibility to combine with MPPT Solar Chargers or Grid-tie PV Inverters.

For examples and more detailed information see the ESS Design & installation manual.

Uninterrupted AC power (UPS function)



In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads.

This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.

Remote Monitoring and Control



Monitor and control your Multi and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop or PC for multiple operating systems.

There is no end to the level of control, via the required Color Control GX or Venus GX, from adjusting your Multi to auto starting a back generator and more...

Technical Features

MultiPlus II 48Volt - 48/3000/35-32 GX

  • PowerControl & PowerAssist: Yes
  • Transfer switch: 32A
  • Maximum AC input current: 32A
  • Auxiliary output: Yes (32A)

INVERTER

  • Input voltage range: 38 – 66 V
  • Output:Output voltage: 230 VAC ± 2%
    Frequency: 50 Hz ± 0,1%
  • Cont. output power at 25°C: 3000VA / 2400W
  • Cont. output power at 40°C: 2200W / 1700W
  • Peak power (W): 5500W
  • Maximum efficiency: 95%
  • Zero load power: 11W
  • Zero load power in AES mode: 7W
  • Zero load power in Search mode: 2W

ENCLOSURE

  • Material & Colour: steel, blue RAL 5012
  • Protection category: IP 21
  • Battery-connection: M8 bolts
  • 230 V AC-connection: Screw terminals 13 mm² (6 AWG)
  • Weight: 26 kg
  • Dimensions (hxwxd): 506 x 275 x 147 mm

CHARGER

  • AC Input: Input voltage range: 187-265 VAC; Input frequency: 45 – 65 Hz
  • Charge voltage 'absorption': 57,6 V
  • Charge voltage 'float': 55,2 V
  • Storage mode: 52,8 V
  • Charge current house battery: 35 A
  • Battery temperature sensor: Yes
  • Programmable relay: Yes
  • Protection:output short circuit, overload, battery voltage too high, battery voltage too low, temperature too high, 230 VAC on inverter output, input voltage ripple too high
  • VE.Bus communication port: For parallel and three phase operation, remote monitoring and system integration
  • General purpose com. port: Yes, 2x

GENERAL

  • Interfaces: VE.Bus Smart dongle (optional)
  • Remote on-off: Yes
  • Operating temperature range: -40 to +65°C (fan assisted cooling)
  • Humidity (non-condensing): max 95%

STANDARDS

  • Safety: EN-IEC 60335-1, EN-IEC 60335-2-29 EN-IEC 62109-1, EN-IEC 62109-2
  • Emission, Immunity: EN 55014-1, EN 55014-2 EN-IEC 61000-3-2, EN-IEC 61000-3-3 IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3

   Downloads

DATASHEET EN [LINK]

  Customer Service

0882 22 82 47
[email protected]
Product Code
PMP482306000
230 V AC-connection
Screw terminals 13 mm2 (6 AWG)
Model
Multiplus
PowerControl
Yes
PowerAssist
Yes
Transfer switch (A)
32A
Output
38 - 66 V
Output voltage: 230 VAC ± 2% - Frequency: 50 Hz ± 0,1%
Cont. output power at 25°C (VA) (3)
3000VA
Cont. output power at 25°C (W)
2400W
Cont. output power at 40°C (W)
2200W
Cont. output power at 65°C (W)
1700W
Peak power (W)
5500W
Maximum efficiency (%)
95%
Zero load power (W)
11W
Zero load power in AES mode (W)
7W
Zero load power in Search mode (W)
2W
AC Input
Input voltage range: 187-265 VAC - Input frequency: 45 – 65 Hz
Charge voltage 'absorption' (V DC)
57.6V
Charge voltage 'float' (V DC)
55.2V
Storage mode (V DC)
52.8V
Charge current house battery (A) (4)
35A
Battery temperature sensor
VE.Bus Smart Dongle (optional)
Auxiliary output (5)
Yes (32 A) Directly connected to the AC input
Programmable relay
Yes
Protection
Output short circuit - overload - battery voltage too high - battery voltage too low - temperature too high - 230 VAC on inverter output - input voltage ripple too high
VE.Bus communication port
For parallel and three phase operation, remote monitoring and system integration
General purpose com. port
Yes, 2x
Remote on-off
Yes
Battery-connection
M8 bolts
Safety
EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2
Emission, Immunity
EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
Automotive Directive
IEC 62040-1, AS 620401.1
Anti-islanding
VDE-AR-N 4105, TOR-D4, AS/NZS 4777.2, NRS 097-2-1, UTE C15-712-1, C10/11, RD 1699-RD 413, G59/3-2, G83/2
Dimensions (D x W x H)
(A x L x P) : 506 x 275 x 147 mm
Net Weight
18Kg
Rated Power VA
3000VA
Rated Power W
2400
Battery Voltage V
48 V
8719076046448