We inform our kind customers that shipments are suspended for the holidays and will resume on January 7, 2025

Argo FET Battery Isolators 100A-2AC Dual Output  Victron Energy
Argo FET Battery Isolators 100A-2AC Dual Output  Victron Energy

Argo FET Battery Isolators 100A-2AC Dual Output Victron Energy

ARG100201020R
Last items in stock
€119.95
VAT included 22 %

€98.32 Vat excl.

Similarly to diode battery isolators, FET isolators allow simultaneous charging of two or more batteries from one alternator (or a single output battery charger), without connecting the batteries together. In contrast with diode battery isolators, FET isolators have virtually no voltage loss. Voltage drop is less than 0,02 Volt at low current and averages 0,1 Volt at higher currents.

 

Argo Diode Battery Isolators 100A dual output

Similarly to diode battery isolators, FET isolators allow simultaneous charging of two or more batteries from one alternator (or a single output battery charger), without connecting the batteries together. In contrast with diode battery isolators, FET isolators have virtually no voltage loss. Voltage drop is less than 0,02 Volt at low current and averages 0,1 Volt at higher currents.

Technical Features

Product code: ARG100201020R
Download Product Datasheet EN

Warranty

2 Years Guaranteed

Connection Diagram

Features

Similarly to diode battery isolators, FET isolators allow simultaneous charging of two or more batteries from one alternator (or a single output battery charger), without connecting the batteries together. Discharging the accessory battery for example will not result in also discharging the starter battery.
In contrast with diode battery isolators, FET isolators have virtually no voltage loss. Voltage drop is less than 0,02 Volt at low current and averages 0,1 Volt at higher currents. When using ARGO FET Battery Isolators, there is no need to also increase the output voltage of the alternator. Care should taken however to keep cable lengths short and of sufficient cross section.

Example:
When a current of 100 A flows through a cable of 50 mm2 cross section (AWG 0) and 10 m length (30 ft), the voltage drop over the cable will be 0,26 Volt. Similarly a current of 50 A through a cable of 10 mm2 cross section (AWG 7) and 5 m length (15 ft) will result in a voltage drop of 0,35 Volt!

Alternator energize input
Some alternators need DC voltage on the B+ output to start charging. Obviously, DC will be present when the alternator is directly connected to a battery. Inserting a Diode or FET splitter will however prevent any return voltage/current from the batteries to the B+, and the alternator will not start.
The new Argofet isolators have a special current limited energize input that will power the B+ when the engine run/stop switch is closed.

Manual, Datasheet and Certifications

  Data Scheet EN[LINK]

For all other documents to download, please visit the web site:
www.victronenergy.com

Assistance

  For service or plant configuration call 0882 22 82 47
  For technical assistance, write to [email protected]
8380000003235

You might also like

Customers who bought this product also bought:

Product added to wishlist
Product added to compare.