Battery Combiners Cyrix Ct 12/24V 230A Victron Energy
CYR010230010R
Last items in stock
€144.61
VAT included
22 %
€118.53 Vat excl.
Cyrix battery combiners are an excellent replacement for diode isolators. The main feature is that there is virtually no voltage loss so that the output voltage of alternators or battery chargers does not need to be increased.
Cyrix Ct 12/24V 230AModel: CRY010230010 |
||
Cyrix battery combiners are an excellent replacement for diode isolators. The main feature is that there is virtually no voltage loss so that the output voltage of alternators or battery chargers does not need to be increased.
Features
Model: CYR010230010R |
Voltage and current plug: 12V-24V 230A |
Internal consumption: 12V= 320mA 24V= 180mA |
Disconnect voltage: Da 11 V a 12,8 V e da 22 V a 25,7 V |
Connecting voltage: With intelligent detection of the trend from 13 V to 13.8 V and 26 V to 27.6 V with intelligent detection of the trend |
StartAssist: Yes (Cyrix remains active for 30 seconds) |
connecting bolts and connecting cables: 13mm (M6) |
Protection: IP54 |
Weight: 270g |
Dimensions (h x l x s) mm: 65 x 100 x 50 |
Warranty
2 Year Warranty |
Certification
Electrical Specification
- |
System Voltage 12v-24v up to a maximum of 230A in office with self-alignment |
- | automatically disconnects the battery when it reaches the minimum voltage or the law of the excessive fluctuations in the download, and you hang yourself as he hears the following voltages 13V for 12V systems and 26V for 24V systems, a sign that the battery is being charged. |
- | Priority charge the starter battery |
- | Bidirectional voltage sensing and power supply from both batteries |
- | Protection against overheating (due to eg. Sustained overload) |
Connection Diagram
Intelligent battery monitoring to prevent unwanted switching
Some battery combiners (also called voltage controlled relay, or split charge relay) will disconnect a battery in case of a short but high amperage load. A battery combiner also may fail to connect a large but discharged battery bank because the DC voltage immediately drops below the disengage value once the batteries are connected. The software of the Cyrix-ct 12/24 does more than simply connect and disconnect based on battery voltage and with a fixed time delay. The Cyrix-ct 12/24 looks at the general trend (voltage increasing or decreasing) and reverses a previous action only if the trend has reversed during a certain period of time. The time delay depends on the voltage deviation from the trend.
12/24 V auto ranging
The Cyrix-ct 12/24 automatically detects system voltage.
Prioritising the starter battery
In a typical setup the alternator is directly connected to the starter battery. The accessory battery, and possibly also a bow thruster and other batteries are each connected to the starter battery with Cyrix battery combiners. When a Cyrix senses that the starter battery has reached the connect voltage it will engage, to allow for parallel charging of the other batteries.
Bidirectional voltage sensing and power supply from both batteries
The Cyrix senses the voltage of both connected batteries. It will therefore also engage if for example the accessory battery is being charged by a battery charger. The Cyrix-ct 12/24 has a dual power supply. It will therefore also close if the voltage on one battery is too low to operate the Cyrix. In order to prevent unexpected operation during installation or when one battery has been disconnected, the Cyrix-ct 12/24 will not close if the voltage on one of the two battery connections is lower than 2 V (12 V battery) or 4 V (24 V battery).
Parallel connection in case of emergency (Start Assist)
The Cyrix can also be engaged with a push button (Cyrix remains engaged during 30 seconds) or a switch to connect batteries in parallel manually. This is especially useful in case of emergency when the starter battery is discharged or damaged.